• Material Handling Banner Application
  • Material Handling Banner
  • Magnetek Material Handling Flex Mini MBT
  • Magnetek Energy Engineered
  • Magnetek Material Handling Collision Avoidance
  • Magnetek Material Handling Flex Mini


IMPULSE®•G+ & VG+ Series 4 Accessories

Interface Card
Analog Inputs
AC Digital Inputs
AC Digital Input & Outputs
DC Digital Inputs
Analog Outputs
Digital Outputs
Encoder (PG) Feedback
24VDC Control Power Unit
Keypad Options
USB Copy Stick
Network Communications Options.

Accessories 
Option Card # & Mounting Location
Instruction
Manual 
Interface Card 

Provides a 120VAC/60Hz optically-isolated interface of 8 digital inputs (binary), 3 Form A dry contact digital outputs, 1 Form C dry contact fault output, 3 analog inputs, 2 analog outputs, pulse input and feedback, and RS-485 Modbus RTU interface.

S4IF-120A60

CN 4-1

Provides a 48VAC/60Hz optically-isolated interface of 8 digital inputs (binary), 3 Form A dry contact digital outputs, 1 Form C dry contact fault output, 3 analog inputs, 2 analog outputs, pulse input and feedback, and RS-485 Modbus RTU interface.

S4IF-048A60

CN 4-1

Provides a 24VAC/60Hz optically-isolated interface of 8 digital inputs (binary), 3 Form A dry contact digital outputs, 1 Form C dry contact fault output, 3 analog inputs, 2 analog outputs, pulse input and feedback, and RS-485 Modbus RTU interface.

S4IF-024A60

CN 4-1

Provides a 120VAC/50Hz optically-isolated interface of 8 digital inputs (binary), 3 Form A dry contact digital outputs, 1 Form C dry contact fault output, 3 analog inputs, 2 analog outputs, pulse input and feedback, and RS-485 Modbus RTU interface

S4IF-120A50

CN 4-1

Provides a 24VDC optically-isolated interface of 8 digital inputs (binary), 3 Form A dry contact digital outputs, 1 Form C dry contact fault output, 3 analog inputs, 2 analog outputs, pulse input and feedback, and RS-485 Modbus RTU interface.

S4IF-024D00

CN 4-1
Analog Inputs 

(13 Bit + Sign)...Provides interface of 3 high resolution analog inputs to the drive. Signal levels (individually selectable): 0 to +/- 10 VDC (20kOhm) or 4 to 20mA (500 ohm). Input resolution: Voltage (1/8192), Current (1/6654).

AI-A3

CN5-A, B, or C
AC Digital Inputs

(4 Bit)...Provides a 120VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive. 

S4I-120A60

CN5-A, B, or C

(4 Bit)...Provides a 48VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive. 

S4I-048A60

CN5-A, B, or C

(4 Bit)...Provides a 24VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive. 

S4I-024A60

CN5-A, B, or C
AC Digital Inputs & Outputs 

(4 Bit)...Provides a 120VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive and 4 120VAC, 1A Form A dry contact relay outputs.

S4IO-120A60

CN5-A, B, or C

(4 Bit)...Provides a 48VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive and 4 120VAC, 1A Form A dry contact relay outputs.  

S4IO-048A60

CN5-A, B, or C

(4 Bit)...Provides a 24VAC/60Hz optically-isolated interface of 4 digital inputs (binary) to the drive and 4 120VAC, 1A Form A dry contact relay outputs.  

S4IO-024A60

CN5-A, B, or C
DC Digital Inputs 

(16 Bit)...Provides a 24VDC optically-isolated interface of 16 digital inputs (binary) to the drive. 

DI-A3

CN5-A, B, or C
Analog Outputs

(11 Bit + Sign)...Provides 2 signals for remote meetering of any two of the drive's "U1" monitors. Additive to the two standard analog outputs. Signal level: 0 to +/- 10 VDC (20kOhm).

AO-A3

CN5-A, B, or C
Digital Outputs 

(8 Channels)...Provides 8 additional digital outputs for use in monitoring the status outputs of the drive. Signal levels: 2 channels of Form A, 250 VAC, 30 VDC, 1 A and 6 channels of PHC, 48 VDC, 50 mADC, Shared Common.

AO-A3

CN5-A, B, or C
Encoder (PG) Feedback 

Single Encoder - Line Driver ...Provides velocity and direction feedback from an encoder. This option is used for motor speed feedback in closed loop flux vector control. A 5 VDC buffered output is also included. Signal levels: 5 or 12 VDC differential line driver with compliments, maximum input frequency of 300 kHz, phases A and B (Z required with some custom software).

PG-X3

CN5-C or B

Single Encoder - Open Collector ...This option provides velocity and direction feedback from an encoder. This option is used for motor speed feedback in closed loop flux vector control. A 24DC buffered output (open collector) is also included. 32 kHz maximum input frequency.

PG-B3

CN5-C or B
Consult Factory
24VDC Control Power Unit

24VDC Control Power Unit - option provides board-level component voltages for the 460V and 575V Series 4 drives when provided with 24VDC from an external, customer-supplied source. It is used to maintain both drive control power and network communications (when utilized).

PS-A10H

CN-6
Consult Factory

24VDC Control Power Unit - option provides board-level component voltages for the 430V Series 4 drives when provided with 24VDC from an external, customer-supplied source. It is used to maintain both drive control power and network communications (when utilized). 

PS-A10L

CN-6
Consult Factory
Keypad Options

The LCD Operator allows the drive to be operated from a remote location up to 3-meters.

JVOP-180

RJ-45 Keypad Port
N/A

The Series 4 Remote Operator Kit allows the LCD Operator to be mounted to an enclosure door. The kit includes one LCD Operator, one mounting bracket and one RJ-45 cable.

S4-RMT-OPER-KIT

CN 4-1
N/A
USB Copy Stick 

The USB Copy Stick allows the drive to connect to the USB port on a PC. It can read, copy and verify drive parameter settings from one drive to another like drive.

JVOP-181

RJ-45 Keypad Port
N/A
USB Copy Unit Kit Contents:

Qty Description
 1 USB Copy Unit (Y-Stick)
1 1 ft USB Cable to connect PC to Y-Stick
1 3 ft Cable with RJ-45 connector on both ends to connect Y-Stick to drive
Driver: USB Copy Stick Driver
Note: This driver is required to be installed on the PC before the Copy Stick can be used. 
Network Communications Option

EtherNet/IP...This option complies with the EtherNet/IP protocol specification. This allows for communication over 10/100 Mbps Ethernet networks. This option has the ability to configure the IP Address from a user specified IP address, from a DHCP host, or from a BootP host. All parameters, diagnostics and operational commands are accessible via EtherNet/IP.

SI-EN3

CN5-A

Modbus TCP/IP...This option complies with the Modbus TCP/IP protocol specification. This allows for Modbus communication over 10/100 Mbps Ethernet networks. This option has the ability to configure the IP Address from a user specified IP address, from a DHCP host, or from a BootP host. All parameters, diagnostics and operational commands are accessible via Modbus TCP/IP. This option supports up to 10 simultaneous PLC/PC connections.

SI-EM3

CN5-A
Consult Factory

PROFIBUS-DP...This option complies with the Profibus- DP protocol specification. All parameters, diagnostics and operational commands are accessible via Profibus. The option board provides a 9-pin (F) type D-Sub connector for easily connecting to a standard Profibus style, shielded twisted-pair cable. Each Profibus network supports up to 99 drives. This option supports all of the Profibus data rates from 9.6 Kbps to 12 Mbps. Up to 32 bytes of input data and 32 bytes of output data are provided per message transaction. Sync and Freeze modes are supported for groups. Profibus DP-V1 support (cyclic and acyclic data exchange). Configurable PPO read and write parameters. The option is configured using parameters within the drive, which allows for easy configuration eliminating the use of hardware switches. Status LEDs are viewable through the front cover, and a monitor has been added to allow for improved diagnostics.

SI-P3

CN5-A
Consult Factory
PROFINET...This option complies to PROFINET I/O device and PROFIDrive profile specifications. It allows connection to a PROFINET network and facilitates the exchange of data via a simple, networking solution that reduces the cost and time to wire and install factory automation devices, while providing interchangeability of like components from multiple vendors. This is a PROFINET Conformance Class A certified interface.

This interface makes it possible to perform the following from a PROFINET master device:
  • Operate the drive
  • Monitor the operation status of the drive
  • Change parameter settings 

GSD/GSDML Files: Download
Note: These files are used to facilitate network implementation.

 SI-EP3

CN5-A
144-27019 
©2019 Magnetek Terms and Conditions